Brand - Aplisens

Measuring range: min. 0 ... 1 bar; max. 0... 400 bar Casing diameter 100 mm Accuracy: 1%


Smart Pressure Transmitter : APC-2000 ALW

Pressure Transducers / Transmitters

Measuring range: min. 0 ... 5 mbar; max. 0... 1000 bar Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA Accuracy: 0,075% (0,04%) Process connection: M20 x 1,5; G 1/2"; 1/2NPT; 1/2NPT F; G1/4”; G 1/2" (flush diaphragm); G 1" (flush diaphragm); M30 x 2 (flush diaphragm); M20 x 1,5 (flush diaphragm); Diaphragm seals;


Smart Pressure Transmitter : PCE-28.Smart

Pressure Transducers / Transmitters

Measuring range: min. 0 ... 5 mbar; max. 0... 1000 bar Output signal: 4...20 mA + protocol HART Accuracy: 0,1% (0,075%) Process connection: M20 x 1,5; G 1/2"; ½ NPT; 1/2NPT F; G1/4”; G 1/2" (flush diaphragm); G 1" (flush diaphragm); M30 x 2 (flush diaphragm); Diaphragm seals;


Smart Pressure Transmitter : APCE-2000PD and APCE-2000PZ

Pressure Transducers / Transmitters

Measuring range: min. 0 ... 5 mbar; max. 0... 1000 bar Output signal: 4...20 mA + protocol HART Accuracy: 0,1% (0,075%) Process connection: M20 x 1,5; G 1/2"; ½ NPT; 1/2NPT F; G1/4”; G 1/2" (flush diaphragm); G 1" (flush diaphragm); M30 x 2 (flush diaphragm); Diaphragm seals;


Pressure Transmitter : PCE-28

Pressure Transducers / Transmitters

Any range from 0 ... 10 mbar up to 0... 1000 bar Output signal: 4...20 mA two-wire; 0...10 V ; 0..2,5 V; 0..3,3 V; 0..5 V; 0,5..4,5 V; Modbus RTU Accuracy: 0,2% (0,16%) Process connection: M20 x 1,5; G 1/2"; ½ NPT; 1/2NPT F; G1/4”; G 1/2" (flush diaphragm); G 1" (flush diaphragm); M30 x 2 (flush diaphragm); Diaphragm seals;


Pressure Transmitter : AS

Pressure Transducers / Transmitters

Measuring range: min. 0 ... 1 bar; max. 0... 25 bar Output signal: 4...20 mA, 0...10 V Accuracy: 0,4% Process connection: M20 x1,5; G 1/2"; R 1/2"; 1/2NPT


Any range from 2,5mbar to 100 mbar Output signal: 4...20 mA, 0..20 mA, 0..10 V Accuracy: 0,2% (1%)


Measuring range: min. 0 ... 2 mbar, max. 0... 70 bar Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA Accuracy: 0,075% (0,04%)


Measuring range: min. 0 ... 0,1mH2O, max. 0... 16 bar Output signal: 4...20 mA + protocol HART; Profibus PA Accuracy: 0,1%


Level measurement

Pressure Transducers / Transmitters

Smart or analog differential pressure transmitters with diaphragm seals for level measurement to pressure tank with gas-filled negative pressure line are recommended transmitters with diaphragm seal mounted on "+" side to pressure tank with liquid-filled negative line are recommended transmitters with diaphragm seal mounted on "-" side and converted output signal.