Counter/Timer : AT8SDN Series

DIN W48×H48mm Star-Delta Timer

DIN W48×H48mm Star-Delta Timer

Star Delta timer AT8SDN Series is the analog timer realizing wide range of power supply (100-240VAC 50/60Hz / 24-240VDC). It is easy to check output status by built-in LED display and to control having wide range of setting time and switching time in order to satisfy customers’ needs. The series is commonly used for starting large capacity motors.

*Realization of wide range of power supply
  : 24-240VAC 50/60Hz, 24-240VDC, 12VDC
*This is upgraded model from AT8SD series.
*Wide range of setting time and switching time.
  UT1(Setting time) : Selectable 5, 10, 50, 100sec
  UT2(Switching time) : Selectable 0.05, 0.1, 0.2, 0.3, 0.4, 0.5sec
*Easy setting of time, switching time on front panel.
*Built-in LED indicator for output status.
*Application : Starting large capacity motors
Specification Table

Model AT8SDN
Function Star-delta timer
Control time setting range 0.5 to 100 sec.
Power supply 100-240VAC 50/60Hz / 24-240VDC
Allowable voltage range 90 to 110% of rated voltage
Power consumption 100-240VAC : 3.2VA, 24-240VDC : 1.5W
Reset time Max. 100ms
Timing operation Power ON start type
Control Contact type contact : SPST(1a), A contact : SPST(1a)
output Contact capacity 250VAC 5A resistive load
Relay Mechanical Min. 10,000,000 operations
life cycle Electrical Min. 100,000 operatlons(250VAC 5A resistive load)
Repeat error Max. ±0.2% ±10ms
ASettlng error Max. ±5% ±50ms
Voltage error Max. ±0.5%
Temperature error Max. ±2%
(그림) Switching time error Max. ±25%
Insulation resistance 100MΩ(at 500VDC megger)
Dielectric strength 2000VAC 50/60Hz for 1 minute
Noise strength ±2kV the square wave noise(pulse width : 1㎲) by the noise simulator
Vibration Mechanical 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) In each of X, Y, Z directions for 1 hours
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz (for 1 min.) In each of X, Y, Z directions for 10 minutes
Shock Mechanical 300m/s²(Approx. 30G) in each of X, Y, Z directions for 3 times
Malfunction 100m/s²(Approx. 10G) in each of X, Y, Z directions for 3 times
Environ-ment Ambient temperature -10 to 55℃, storage: -25 to 65℃
Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
Approval CE,UL
Unit weight Approx. 90g
※Environment resistance is rated at no freezing or condensation.