| Counting mode |
Add, Subtract or Add/Subtract (individual input, 90° quadrature input) |
| Inputs |
1 x Open Collector (sink current approx. 11 mA) or voltage (input impedance 7 kΩ) |
| Display |
Blue STN LCD with white backlight; 6 digits, size of digits 10 mm x 5 mm |
| Data memory |
EEPROM type, 10 years, can be used about 10000 times |
| Input levels |
OC: low 0-4V; voltage: low 0-4V, high 6-30V (available to duplex wire DC sensor) |
| Input frequency |
30Hz, 1kHz, 5kHz, 10kHz (selectable) |
| Displayed values range |
-99999 - 999999, decimal point position: 0.0, 0.00, 0.000 or no decimal point |
| Power consumption |
2,5 W for 24V DC; 7 VA for 240V AC |
| Output |
1 or 2 relays 250V AC 5A / 30V DC max. 5A |
| Reset |
Front panel reset, Remote reset (2 ms or 20 ms, selectable), Auto-reset |
| Protection class |
IP 54 (panel surface) |
| Operating temperature |
-10°C ÷ +50°C |
| Case |
panel |
| Power supply |
12 - 24V DC -15%, +10% or 100 - 240V AC -15%, +10% |
| Panel cut-out dimensions |
44,5 x 44,5 mm |
| Case dimensions |
48 x 48 x 64 mm (DC version), 48 x 48 x 100 mm (AC version) |