Information
Puls Transmitter PD-20 S is designed to combine reliable weight information from process vessels with extremely easy operation and setup. A wide range of strain gauge load cells can be connected and output is provided in the common 4... 20 mA signal format. With its DIN-rail mount, it is easy to place. It is an economic aplifier for control and weighing applications in the industry."
Tachnical specification
|
GENERAL |
|
|
Power Supply |
18 - 36 VDC |
|
Inputs |
1 Unit Digital |
|
Outputs |
16 Bit Analog Output (0-10V, 4-20mA , 0-20mA) |
|
Protection Class |
IP 54 |
|
DISPLAY |
|
|
Display |
7 mm 7 Segment DISPLAY |
|
Display Step |
x1 , x2 , x5, x10, x20, x50 |
|
Decimal Display |
0.1, 0.01, 0.001 |
|
Keypad |
4 Units Membrane Type |
|
A / D CONVERTER |
|
|
Type |
24 bit Delta-Sigma ADC |
|
Converting Speed |
100 HZ |
|
Display Precision |
1/100.000 |
|
FILTER AND CALIBRATION |
|
|
Digital Signal Filter |
It is internal filter of ADC. |
|
Anti-vibration Filter |
Special Filter for Vibrated Environments |
|
Parametric Calibration |
Done while being connected to the Load Cell |
|
Weighted Calibration |
With standard weights. |
|
LOAD CELL |
|
|
Power Supply |
10 V DC |
|
Number of Load Cells |
4 Units 350 Ω |
|
Output Signal at Max Load |
≤ 4 mV/V |
|
Connection |
Connection with 4 or 6-core cable. |
|
COMM. INTERFACE |
|
|
Serial Port - Modbus |
RS 485 |
|
Serial Port - Free Protocol |
RS 232 |
|
AMBIENT AND EQUIPMENT |
|
|
Operating Temperature |
-10 °C ~ +40 °C |
|
Humidity |
%85 |
|
Box |
RAIL MOUNT SPECIAL PLASTIC TYPE |
![]() |
PD-20 S Loadcell Transmitter Catalog