BLH NOBEL : KOSD

Suitable for force measurement applications
Simple installation
The cylindric shape makes it easy to replace an axis
ATEX approved for hazardous areas
Applications in cranes
Tension measurement
Offshore

| LOAD CELL | RANGE kN | ØA | ØB | ØC | D | E | F | G | H | J | K | L | M |
| KOSD-101 | 1000 | 99 | 97 | 94.5 | 352 | 38 | 10 | 9.5 | 3 | 40 | 183 | 3 | 3.15 |
| KOSD-107 | 1000 | 99 | 97 | 94.5 | 189 | 38 | 10 | 9.5 | 3 | 40 | 20 | 3 | 3.15 |
| KOSD-115 | 2000 | 130 | 127.5 | 124 | 279 | 38 | 10 | 15 | 9.5 | 45 | 100 | 9.5 | 4.15 |
TECHNICAL CHARACTERISTICS KOSD
| Rated load (R.L.): | 1000, 2000 kN |
| Combined error: | ±1% of R.O. |
| Repeatability: | 0.5% of R.O. |
| Safe overload: | 100% of R.L.* |
| Ultimate overload*: | 200% of R.L. |
| Safe sideload: | 100% of R.L. |
| Ultimate sideload: | 200% of R.L. |
| Recommended input: | 10 Vdc/ac |
| Input voltage maximum: | 18 Vdc/ac |
| Input resistance: | 700 ± 5 Ohm |
| Output resistance: | 700 ± 5 Ohm |
| Rated output (R.O.): | about 2 mV/V |
| Zero balance: | ±5% of R.O. |
| Temperature range: | -30 to +70 °C |
| Temp. effect (-10°C to +50°C) on output: | ±0.04% of output/°C |
| Temp. effect (-10°C to +50°C) on output: | ±0.04% of R.O./°C |
| Insulation resistance at 200 V DC: | > 4 G Ohm |
| Material: | Stainless steel |
| Hardness: | 350 ± 20 HB |
| Electrical connection: | 10m shielded four conductor cable |
| Degree of protection: | IP67 |
| ATEX certified versions for use in explosive atmospheres are available: II 1GD. EEx ia IIC T4 Tamb = 60°C F/2 | |
| * Referring to recommended loading case |

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi