Electromagnetic Water Meter : SU Series
Feature
Measurement feature | Continuous measurement of large flowrates |
---|---|
Measurement range | 1:200 |
Measurable water | City water, plant water, agricultural water |
Meter connection method | Wafer type *1, *2 |
Body material | Stainless steel pipe |
Flow path | Pipe structure |
Enhanced Durability! Lnnovative water meter for the new-era
As consumption of water has increased in the recent years, an advanced water meter has been desired for the use of long time and stable high accuracy measurement with trouble-free operation. Responding to these needs, Aichi has conducted proprietary research over and over and has succeeded in developing the world′s first electromagnetic water meter “SU Series” and “SY Series” that provides 8 years of non-stop service with built-in battery. These water meters for the new-era are suitable for water control with innovative enhanced durability that expands the world of measurement.
Outstanding features that expand the world of measurement
Outstanding durability with no moving parts
Since there are no rotating or sliding parts such as vane wheel or indication gears, troubles caused by wear of moving parts and intrusion of foreign substances are eliminated. Therefore, stable measuring accuracy can be maintained over a long period of time.
High accuracy measurement whether large continuous or small flowratesThe SU Series has almost no head pressure loss at maximum flowrate measurement, it is suitable for measuring flowrates of large continuous water supply and distribution. The SY Series is capable of measuring small flowrates with high accuracy owing to its special structure.
Wider measurement rangeThe measurement range is as wide as 1:200 for the SU Series, and 1:1000 for the SY Series. High-accurate measurement from very small (min. accurate flowrate) to large (max. flowrate) flowrates is possible.
8 years of continuous operation with a built-in batteryThe power consumption has been reduced to 1/1000 (according to Aichi's comparison data) from the conventional general electromagnetic flowmeter, and with a built-in lithium battery applied, 8 years of continuous measurement is realized. Consequently, there is no need of maintenance during this period.
Constant display on easy-to-read LCDBright and large LCD have been incorporated for the digital display of integrated flow and instantaneous flowrate values of all times. By utilizing such instantaneous flowrate value, flowrate adjustment of water supply and distribution can be easily performed.
Free installation position allows installation anywhereHaving no mechanical moving parts, the meter can be installed on a horizontal, vertical or inclined position, allowing installation anywhere with very little restriction for its location.
All stainless steel body with outstanding durabilityBoth the compact design wafer type (SU)* and easy-to-install flange type (SY) are made of all stainless steel body having the feature of long life.
*The SU with 250, 300 and 350mm nominal diameters are flange types.
Since these meters are equipped with electronic statement signal output function, installation of transmitter for specific use will enable flexible corresponding to various systems such as remote meter reading, automatic meter reading, as well as monitoring and controlling.
Overview
Item | Nominal diameter | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
50 | 65 | 75 | 100 | 125 | 150 | 200 | 250 | 300 | 350 | ||
Flow-rate range | Max. flow-rate (2qp)(m3/h) |
60 | 90 | 120 | 180 | 240 | 400 | 600 | 800 | 1000 | 1200 |
Standard flow-rate (qp)(m3/h) |
30 | 45 | 60 | 90 | 120 | 200 | 300 | 400 | 500 | 600 | |
Transitional flow-rate (qt)(m3/h) |
6 | 9 | 12 | 18 | 24 | 40 | 60 | 80 | 100 | 120 | |
Min. flow-rate (qmin)(m3/h) |
0.9 | 1.35 | 1.8 | 2.7 | 3.6 | 6 | 9 | 12 | 15 | 18 | |
Min. accurate flow-rate (qc)(m3/h) |
0.3 | 0.45 | 0.6 | 0.9 | 1.2 | 2 | 3 | 4 | 5 | 6 | |
Measurement starting flow-late (qs)(m3/h) |
0.15 | 0.23 | 0.3 | 0.45 | 0.6 | 1 | 1.5 | 2 | 2.5 | 3 | |
The meter does not measure a flowrate less than the measurement starting flowrate (qs). The qs to qmin flowrate range is not within the calibration tolerance. |
|||||||||||
Max. limit flow-rate (qL)(m3/h) |
70 | 120 | 160 | 280 | 440 | 650 | 1100 | 1140 | 1140 | 1200 | |
The 2qp to qL flowrate range is not within the calibration tolerance. | |||||||||||
Pressure drop at max. flow-rate (MPa) |
Not more than 0.02 at the upper limit flowrate of the flowrate range | 0.03 | 0.035 | ||||||||
Working pressure (MPa) |
Not more than 2 (Approx. 20kgf/cm2)(‘P2’ is printed on a register plate.) | Not more than 1 (Approx. 10kgf/cm2) (“P1” is printed on a register plate.) |
|||||||||
Display | Integrating flow (m3) | 999999.999 | 9999999.99 | ||||||||
Instantaneous flow-rate (m3/h) |
999.9 | 9999 | |||||||||
Meter weight (kg) | 3.5 | 4 | 5 | 6 | 8 | 10 | 15 | 47 | 68 | 98 |
Item | |||
---|---|---|---|
Display | No-water warning mark | ![]() |
|
Low-battery alarm mark | ![]() |
||
Measurement stop alarm mark | ![]() |
||
Measured fluid | Suitable working temperature (°C) |
0 to +30 | |
Fluid conductivity rate (μs/cm) | 50 or more | ||
Power supply and battery life | Lithium battery (Nominal 3.6V), battery life approx. 8 years (At average environmental temperature of 20°C) | ||
Environmental temperature range (°C) | -10 to +55 (The battery life is shortened at higher temperature.) | ||
Waterproof structure | IP68 (JIS C 0920) | ||
Piping method | Wafer type (Nominal diameter 250, 300 and 350mm are flange type; JWWA standard flange or JIS 10K standard flange.) | ||
Meter installation position | Free (Horizontal, vertical and inclined installation are possible.) | ||
External output | SU-GN type | No external output function (Only field display) | |
SU-GC type | Electronic statement signal for exclusive independent receiver (SR-4 type) | Transmitter: MX35 type | |
SU-GM type | Open drain unit pulse signal | Transmitter: MX39 type | |
SU-GL type | 8-bit electronic statement signal (The signal widely diffused in Japan for water and gas meters), open drain unit pulse signal | Transmitter: MX38 type |
Accuracy
Dimensions
External Dimensions

Transmitter specifications MX Series
Signal | Electronic statement signals for exclusive independent receiver (SR-2 type) |
---|---|
Number of wires | 2 |
Transmitting distance | 50m with standard cable |
Life | Approx. 10 years |
Signal | Open drain unit pulse |
---|---|
Pulse ON time | 100±10ms |
Pulse unit | 100L/P or 1m3/P (10m3/p·special specification) |
Number of wires | 2 |
Transmitting distance | 200m with standard cable |
Life | Approx. 10 years |
Signal | 1) Ver. 2.6A Only 8-bit electronic statement 2) Ver. 2.6A 8-bit electronic statement and open drain unit pulse |
---|---|
Number of wires | 2 wires for 1), 4 wires for 2) |
Transmitting distance | 200m with standard cable (When connected with independent type receiver QA8D-1R) |
Life | Approx. 8 years (Differs according to number of readings) |